ABB.1SAM340000R1009

聲明:您必須遵守我們的協(xié)議,如果您下載了該資源行為將被視為對《電天下賬號管理規(guī)范》全部內(nèi)容的認(rèn)可,本網(wǎng)站資源來自原創(chuàng),僅供用于學(xué)習(xí)和交流,請勿用于商業(yè)用途。如有侵權(quán)、不妥之處,請舉報本資源,我們將及時審核處理!

ABB.1SAM340000R1009

部件編號
ABB.1SAM340000R1009
制造商
ABB
類型編號
MS132-6.3T
名稱
MS132-6.3T Circuit-breaker for primary transformer protection
描述
The circuit breaker for transformer protection MS132-6.3T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 6.3 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.
訂貨號
1SAM340000R1009
分類
電氣元件>安全設(shè)備>常規(guī)
數(shù)據(jù)類型
基本信息 邏輯支路
創(chuàng)建時間
2023-11-15 10:50:15
0/200
復(fù)制下方鏈接,分享給好友同事
或微信掃描下方二維碼一鍵分享給好友
復(fù)制下方鏈接,分享給好友同事
或微信掃描下方二維碼一鍵分享給好友
關(guān)注或聯(lián)系我們
官方公眾號
400-6699-000 工作日 9:00-17:00
利馳數(shù)字科技(蘇州)有限公司
VIP
問答
客服
反饋
賺錢
ABB.1SAM340000R1009
資源詳情
評論建議
ABB.1SAM340000R1009
SuperWORKS IA自動化軟件專享
基本信息 邏輯支路
作品詳情
瀏覽:11
收藏:0
更新時間:2023-11-15
格式:LDZ
作品介紹
部件編號
ABB.1SAM340000R1009
制造商
ABB
類型編號
MS132-6.3T
名稱
MS132-6.3T Circuit-breaker for primary transformer protection
描述
The circuit breaker for transformer protection MS132-6.3T is a compact 45 mm width device designed to protect control transformers on the primary side. This device has a rated operational current of Ie = 6.3 A. It allows fuse-less protection against overload and short-circuit. The short-circuit current setting is fixed to 20 times the rated operational current to handle the high inrush current generated by transformers. The device allows manually connect and disconnect the transformer from the mains thanks of its built-in disconnection function. The circuit breaker for transformer protection offers a rated service short-circuit breaking capacity of Ics = 100 kA at 400 VAC and a trip class 10. Further features are temperature compensation, trip-free mechanism, rotary handle with a clear switch position indication and short circuit trip indicator. The handle is lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts, undervoltage releases, shunt trips, power in-feed blocks are available as accessory.